Basic information
Function: Changing the measured pressure will cause the sensor diaphragm to deflect. This change is converted to a 4-20 mA output signal.
Technical parameters of the absolute pressure transmittors
- Type of measured pressure value: absolute
- Min. measured pressure value: 0 bar
- Max. measured pressure value: 2.5 bar
- Connection type: male thread 1/4" BSP
- Accuracy: <0.5 %
- Output: 4 - 20 mA
- Supply voltage: 24 VDC
- Connector: Hersman DIN43650
- Case material: Stainless steel AISI 304
- Membrane material: Stainless steel AISI 316
- Sensor material: Silicon
- Degree of protection IP: IP 65
- Temperature range of the measured medium: -25 ° C ~ +85 ° C
- Response time: 10 ms
- Influence of ambient temperature: 0-50 ° C from the upper limit of the range <0.5%, -20 ° C to +80 ° C from the upper limit of the range <1%
- Seal: Viton
- Overload capacity: 150% of the measured range
- Suitable for materials compatible with stainless steel AISI 304.
Other options for connecting absolute pressure sensors
Possibility of delivery with separating clamp membrane made of stainless steel AISI 316L - easy sanitization of the meter.
Most common use
- Light industry
- Medical devices
- Regulation of pressure processes
- Hydraulic and air pressure systems
- Cooling, air conditioning
- Compressors
- Food and beverage industry
More from the category
Absolute pressure transmitter, connection 1/4" BSP, 24VDC