Pneumatically operated butterfly valves, threaded (G-G), DIN 11851

A pneumatic single-acting actuator (air/spring) is used for opening and closing direct valves with compressed air (recommended value for safe opening of the damper is 5 - 7 bar). The pneumatic actuator's spring serves to close direct damper (without control air pressure) or indecreaseontrol air pressure for a safe closing of the valve (damper).

To control the pneumatic actuator, the actuator must be supplemented with a pilot (electromagnetic) valve for controlling the compressed air supply. The damper can also be equipped with inductive sensors to indicate the actual damper position (open/closed). This configuration allows you to operate the damper via a feedback control system in which position the damper is located.

The position of the flap is also indicated visually by a pin that is mounted on the control shaft.

Price from 3 954,50 Kč
Prices are stated without VAT
Variant
Code
Availability
Price without VAT
Quantity
DN20 BVTP_20
BVTP_20
in stock
3 954,50 Kč
Detail
DN25 BVTP_25
BVTP_25
in stock
3 954,50 Kč
Detail
DN32 BVTP_32
BVTP_32
in stock
4 064,50 Kč
Detail
DN40 BVTP_40
BVTP_40
in stock
4 120,60 Kč
Detail
DN50 BVTP_50
BVTP_50
in stock
4 292,20 Kč
Detail

Technical Parameters of Pneumatic Actuator

  •      Actuating shaft diameter 17 mm.
  •      Height of actuator with shaft: 185 mm
  •      The diameter of drive: 85.3 mm
  •      Torque: 20 Nm
  •      Operating pressure: 4–8 bar (recommended 5–7 bar)
  •      Working temperature: –10 ° C to 100 ° C
  •      Operation speed: 1.5 sec / 90 °
  •      Material: AISI 304

Pneumatic single-acting actuator (air/spring) is used for opening and closing direct valves with compressed air (recommended value for safe opening of the damper is 5 – 8Bar). The spring of the pneumatic actuator serves for the closing of the direct damper (without control air pressure) or in case of decreasing control air pressure for a safe closing of the valve (damper).

To control the pneumatic actuator, the actuator must be supplemented with a pilot (electromagnetic) valve for controlling the compressed air supply. The damper can also be equipped with inductive sensors to indicate the actual damper position (open/closed). This configuration allows you to operate the damper via a feedback control system in which position the damper is located.

The position of the flap is also indicated (visually) by a pin which is mounted on the control shaft.

We care about your privacy

We need your consent to the use of cookies so that we can better customize the website for you and make it easier to use. By clicking the "I agree" button, you agree to save cookies in your browser, thanks to which you can use the website's potential to the fullest. Details can be found on the page "Information about cookies".